<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>7000</ErrorNumber>
<ErrorFamily>Carriage</ErrorFamily>
<ErrorMessage>
CARRIAGE: Limit switches reporting carriage is both HOME and AWAY
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The carriage firmware detected that both the HOME and AWAY optical interrupters are
tripped. This is likely caused by some problem with the HOME/AWAY board or cable.
In fact, if the HA-BP cable is not connected and its cable detection is disabled (i.e.
masked), this error will be reported.
</text></DescriptionText>
<DescriptionText><text>
First check that the HA-BP cable detect is not masked (use the "mask" command).  If it
was masked, and removing the mask ("mask off ...") caused a HA-BP cable error, the
missing cable is the cause of the problem.
</text></DescriptionText>
<DescriptionText><text>
If no HA-BP cable error is reported, the HA-BP cable should still be inspected and
reseated.  If the error persists, and no foreign objects are blocking the switches, the
HOME/AWAY board, HA-BP cable and ALE should be replaced one at a time.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Check if there are slipsheets, plates, etc stuck around the exposure head.  If not, record
error message and call Creo service.
</text></DescriptionText>
</OperatorAction>
<Cause>
Disconnected or improperly seated HOME/AWAY cable (HA-BP)
</Cause>
<Cause>
Faulty HOME/AWAY board, cable, or ALE
</Cause>
<Cause>
Foreign object tripping switches
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:28 2008 PST
</Updated>
<Links>
</Links>
</Error>